User Manual
Wireless Hand-held Vacuum Cleaner
- Product Overview
1.1 Product Diagram
1.2 Product Packing List
Main Unit |
Battery Pack |
Extension Tube |
Scrubbing Brush |
Flat Suction |
Square brush body |
Square brush tube |
Adapter |
Instructions |
1.2 Product Technical Parameters
Product |
Technical parameters |
Operating voltage (V) |
22.2DC |
Operating current (A) |
6.5 |
Battery capacity (mAh) |
2000 |
Dust cup volume (L) |
0.6 |
Vacuum degree (kPa) |
≥8 |
Use time (Min) |
25-40 |
Charging time (H) |
4—5 |
Main unit size (mm) |
276*109*200 |
Main unit weight (g) |
1035 |
- Component installation instructions
Instructions for battery pack installation
*After aligning the battery pack card slot with the main unit card slot, push it in and hear the click sound, indicating installation is successful (as shown in the figure)
Instructions for extension pipe
*Installation of main unit and extension pipe: Insert the end of aluminum pipe straight into the suction port of main unit. When hearing the button clicking sound, the installation is successful (as shown in the figure)
*Disassembly of main unit and extension tube: Hold the main unit with one hand and pull it out while pressing the buckle button of extension tube with the other hand (as shown in the figure)
Instructions for electric scrubbing brush
*Installation of electric scrubbing brush: Insert the connector of electric scrubbing brush straight into the hole of extension pipe. When hearing the button clicking sound, the installation is successful (as shown in the figure)
*Disassembly of extension tube and scrubbing brush: Hold the extension tube with one hand and pull it out while pressing buckle button of scrubbing brush buckle with the other hand (as shown in the figure)
Instructions for accessory brush
Flat suction is suitable for cleaning narrow spaces, e.g. corner, aluminum alloy door and window frame, drawer, car cushion, keyboard and other places. Two-in-one square brush is suitable for cleaning the surface of soft materials, e.g. curtains, cloth, sofa, bed and etc. Flat suction and square brush use: flat suction and square brush directly cover the suction port of main unit for use (as shown in the figure)
Flat suction and square brush can also be used with extension tube for cleaning ceiling and roof.
- Product Use Instructions
3.1 Product Charging
This product supports two charging modes:
- The battery pack is inserted into the adapter charging socket hole separately for charging((as shown in the figure)
- The battery pack is installed on the whole machine, and the adapter is inserted into the charging hole of the battery pack to charge (as shown in the figure)
About Indicators
When the product is operating The number of three indicator lights indicates battery consumption, |
When the product is charging The number of three indicator lights indicates the full charge of the battery, |
When the product is fully charged When all the three indicators light on and off, it indicates that the charging is completed |
When low power of the product When an indicator light flashes, it indicates that the power is low and needs to be stopped for charging |
Notes
* Please charge the battery with the original adapter for over 3 hours every 3 months after delivery.
* It is not allowed to charge the battery pack and the whole machine for a long time. Once charging is completed (after the indicator light goes off), stop charging, otherwise the battery may become hot, deformed, burnt and have other hazards.
* After the battery is deeply discharged, it is recommended to store it after charging. Long term power shortage will affect the service life of battery.
- 2 Preparation Work
Depending on different cleaning areas, select accessories as needed (See the installation instructions for details)
- 3 Start work
The on/off key of the machine is the red button. After pressing this button, the machine starts to operate. Release the button and the machine stops working. The button on the power display panel serves as the high and low gear button. Press the high and low gear button, the red indicator will light on, and the machine will operate in high gear, featuring large suction power. Press the high and low gear button again, the red indicator will go off, and the machine will operate in low gear, featuring small suction power. Adjust the high and low gear of the machine as needed.
3.4 Remove ash in dust cup
After stopping the machine, press the red button on the side of dust cup to remove the ash and dirt. Close the bottom of the cup to use the machine again.
Scrubbing brush cleaning
To maintain the performance of scrubbing brush, it is recommended that the roller brush should be cleaned once after the scrubbing brush is used for 4-5 times.
* Turn the coin buckle and stop at the open position.
* Loosen the right cover of scrubbing brush.
* Take out the roller brush, clean it and put it into the scrubbing brush.
Take out and clean the top roller brush, loosen the right cover of the floor brush, and loosen the coin buckle
- Troubleshooting
Common fault analysis and processing
Fault phenomenon |
Possible causes |
Solutions |
The vacuum cleaner doesn't work |
Low battery |
Charge the battery |
The suction port is blocked |
Clean the product suction port |
|
The product suction decreases |
The filter assembly is covered with dusts |
Clean the dust cup and filter components |
Filter Hepa is blocked |
Clean or replace filter Hepa |
|
Abnormal sound generated from motor operation |
The dust suction pipe or filter component is blocked |
Clean the extension tube or filter component |
The product cannot be charged |
The adapter and battery pack are not well connected |
Check and connect again |