Cart
/

User Manual XCQH004 EN

User Manual

Wireless Hand-held Vacuum Cleaner

 

  1. Product Overview

1.1 Product Diagram

 

1.2 Product Packing List

Main Unit

Battery Pack

Extension Tube

Scrubbing Brush

Flat Suction

Square brush body

Square brush tube

Adapter

Instructions

 

 

1.2 Product Technical Parameters

Product

Technical parameters

Operating voltage (V)

22.2DC

Operating current (A)

6.5

Battery capacity (mAh)

2000

Dust cup volume (L)

0.6

Vacuum degree (kPa)

≥8

Use time (Min)

25-40

Charging time (H)

4—5

Main unit size (mm)

276*109*200

Main unit weight (g)

1035

  1. Component installation instructions

Instructions for battery pack installation

*After aligning the battery pack card slot with the main unit card slot, push it in and hear the click sound, indicating installation is successful (as shown in the figure)

Instructions for extension pipe

*Installation of main unit and extension pipe: Insert the end of aluminum pipe straight into the suction port of main unit. When hearing the button clicking sound, the installation is successful (as shown in the figure)

*Disassembly of main unit and extension tube: Hold the main unit with one hand and pull it out while pressing the buckle button of extension tube with the other hand (as shown in the figure)

Instructions for electric scrubbing brush

*Installation of electric scrubbing brush: Insert the connector of electric scrubbing brush straight into the hole of extension pipe. When hearing the button clicking sound, the installation is successful (as shown in the figure)

*Disassembly of extension tube and scrubbing brush: Hold the extension tube with one hand and pull it out while pressing buckle button of scrubbing brush buckle with the other hand (as shown in the figure)

Instructions for accessory brush

Flat suction is suitable for cleaning narrow spaces, e.g. corner, aluminum alloy door and window frame, drawer, car cushion, keyboard and other places. Two-in-one square brush is suitable for cleaning the surface of soft materials, e.g. curtains, cloth, sofa, bed and etc. Flat suction and square brush use: flat suction and square brush directly cover the suction port of main unit for use (as shown in the figure)

Flat suction and square brush can also be used with extension tube for cleaning ceiling and roof.

  1. Product Use Instructions

3.1 Product Charging

This product supports two charging modes:

  1. The battery pack is inserted into the adapter charging socket hole separately for charging((as shown in the figure)
  2. The battery pack is installed on the whole machine, and the adapter is inserted into the charging hole of the battery pack to charge (as shown in the figure)



About Indicators

When the product is operating

The number of three indicator lights indicates battery consumption,

When the product is charging

The number of three indicator lights indicates the full charge of the battery,

When the product is fully charged

When all the three indicators light on and off, it indicates that the charging is completed

When low power of the product

When an indicator light flashes, it indicates that the power is low and needs to be stopped for charging

 

Notes

* Please charge the battery with the original adapter for over 3 hours every 3 months after delivery.

* It is not allowed to charge the battery pack and the whole machine for a long time. Once charging is completed (after the indicator light goes off), stop charging, otherwise the battery may become hot, deformed, burnt and have other hazards.

* After the battery is deeply discharged, it is recommended to store it after charging. Long term power shortage will affect the service life of battery.

  1. 2 Preparation Work

Depending on different cleaning areas, select accessories as needed (See the installation instructions for details)

  1. 3 Start work

The on/off key of the machine is the red button. After pressing this button, the machine starts to operate. Release the button and the machine stops working. The button on the power display panel serves as the high and low gear button. Press the high and low gear button, the red indicator will light on, and the machine will operate in high gear, featuring large suction power. Press the high and low gear button again, the red indicator will go off, and the machine will operate in low gear, featuring small suction power. Adjust the high and low gear of the machine as needed.

3.4 Remove ash in dust cup

After stopping the machine, press the red button on the side of dust cup to remove the ash and dirt. Close the bottom of the cup to use the machine again.



Scrubbing brush cleaning

To maintain the performance of scrubbing brush, it is recommended that the roller brush should be cleaned once after the scrubbing brush is used for 4-5 times.

* Turn the coin buckle and stop at the open position.

* Loosen the right cover of scrubbing brush.

* Take out the roller brush, clean it and put it into the scrubbing brush.

 

Take out and clean the top roller brush, loosen the right cover of the floor brush, and loosen the coin buckle



  1. Troubleshooting

Common fault analysis and processing

Fault phenomenon

Possible causes

Solutions

The vacuum cleaner doesn't work

Low battery

Charge the battery

 

The suction port is blocked

Clean the product suction port

The product suction decreases

The filter assembly is covered with dusts

Clean the dust cup and filter components

 

Filter Hepa is blocked

Clean or replace filter Hepa

Abnormal sound generated from motor operation

The dust suction pipe or filter component is blocked

Clean the extension tube or filter component

The product cannot be charged 

The adapter and battery pack are not well connected

Check and connect again