Cart
/

SG/MY-DEHUMIDIFIER CUSH006 USER MANUAL

SPECIFICATIONS

Name

Rated voltage

Max rated Input Power

Rated Frequency

Maximum Pressure

Water Tank Capacity

Appliance Classes

DEHUMIDIFIER

220-240V~

200W

50Hz

High side 3.2MPa;

Low side 0.7MPa

2.0L

Class I

 

ILLUSTRATION

①Control panel

②Three-color indicator

③Front shell

④Casters

⑤Right panel

①Rear shell

②Handle

③Air inlet (with filter)

④Water tank

⑤Continuous drainage

⑥Air outlet

⑦Power cord

⑧Left panel

 

ASSEMBLY

 

  1. Place the product on a firm, level surface in an area with at least 30cm of free space around it for proper air circulation.
  2. Never install the product where it could be subject to:
  • Heat sources such as radiators, heat registers, stoves or other products that produce heat.
  • An area where oil or water may be splashed
  • Direct sunlight
  • Mechanical vibration or shock
  • Excessive dust
  • Lack of ventilation, such as cabinet or bookcase
  • Uneven surface

 

OPERATION

  1. Control panel

 

 

After switching on, all the indicators and the screen will be on for 1 second and then off. After a buzzer, the power indicator will be on and the machine will be in standby mode.

Press this button, the machine starts to run at initial humidity (60%RH), and its default mode is auto mode and high wind.

Press this button again, the machine will stop running, and the fan will be closed.

 

Auto mode-continuously drying mode-sleeping mode cycle; press once to switch modes from one to another and the corresponding indicator will light up.

Auto mode: when environmental humidity ≥ set humidity +3%, the fan starts working and compressor starts working after 3 seconds.

When environmental humidity ≤ set humidity -3%, the compressor stops working and and the fan will shut down afterwards.

Both fan speed and humidity can be adjusted under auto mode.

Continuously drying mode: The machine continues to run, but the humidity can not be adjusted.

Sleeping mode: Touch the sleep button,andthe button lights up, entering sleep mode. If there is no operation for 10 seconds, all indicators turns dark gradually and the wind speed is automatically switched from high to low. Touch any button to wake up the indicator. Touch sleep button again to exit the sleep mode.

In sleep mode, the wind speed is not adjustable, but the humidity is adjustable.

 

In auto mode or sleep mode, you can press this button to adjust humidity: every time you press the humidity increase by 5%, within the cycle of 30%-80%.

Long press this button to see the current room temperature. Double eight lights will display the current room temperature for 5 seconds, then return to current humidity display.

 

Press this button to set a timer of 0-24 hours. The interval is 1 hour. Each time you press this button, the timer increased 1 hours and then the corresponding number will be displayed on the screen. If the number is “00”, timer is canceled. The indicator turns out.

The timer LED is on during the timing period. After the timing is over, the timer LED turns off automatically.

In the running state, set the time to turn off the machine;

in the standby state, set the time to turn on the machine.

 

The wind speed can only be adjusted in automatic mode. Press this button to switch between high and low wind speed. The corresponding wind speed indicator will light up.

 

Long press this button to open the child lock function. The child lock indicator light is on. All the buttons are locked and cannot be operated. Press this button again, the indicator light will go out, and the button will be restored.

Open the child lock function, as long as the shutdown or power off will automatically cancel the child lock function.

  1. LED 3-color indicator:

Ambient Humidity<45%, the light shows Blue

45≤Ambient Humidity≤65% , the light shows Green

Ambient Humidity>65% , the light shows Red

 

MAINTENANCE

  1. Water tank
  • When the tank is full, The productwill make a buzzing sound, and the “Water Full” light will turn on.
  • Press the POWER button to turn off the product.
  • Pull the water tankout of the body of the
  • Empty the water into an area with a drain or outside.
  • Clean the inside of the tank as well as the outside.
  • Place the empty tank back into the product.
  • Press the POWER button to resume operating.
  • If the Water Full light does not shut down, check if the float is correctly in place.

Warning

  • Do not discard water tank magnets and plastic rivets. Otherwise, the machine will not automatically stop working when the water tank is full, and the condensed water will overflow and damage the floor of the room.
  • Please be sure to clean the condensed water in the water tank before resetting the working mode of the machine.
  • If the water tank is dirty, rinse it with clean water. Avoid using detergents, steel balls, chemical dust removers, diesel oil, benzene, diluentor other solvents. Otherwise, the water tank will be damaged and leak
  • Place the empty tank back into the product. Otherwise, the water full indicator may remain red, preventing the machine from restarting.
  1. Continuous draining

For continuous operation or unattended humidification, please connect the attached drain hose to the product. Condensate water can be automatically flow into a bucket or drain by gravity.

  • Straighten the drainage pipe
  • Insert one end of the hose into the cistern hole and connect the other end to the bathroom, a bucket-like container, or the outside.

Warning

  • Please do not block the drain or drain pipe. If blocked, condensed water will flow into the water tank.
  • Please do not bend the drain pipe. The drain pipe should be placed lower than the outlet.
  • The drain pipe shall be securely connected to the outlet.
  1. The air filter

Dust, if accumulated, may damage the product. The air filter needs to be cleaned regularly. The air filter is removable for easy cleaning. Do not operate the product without the air filter as it may contaminate the evaporator.

  • Take the water tank from the body, and then pull out the filter from the bottom of the rear shell;
  • Use a vacuum cleaner to gently suck the dust on the surface. If the filter is very dirty, wash it with water and a soft detergent and dry it thoroughly afterwards.
  • Put the filter back.

 

CAUTION

  1. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  2. The appliance shall be disconnected from its power source during maintenance.
  3. Always operate the product from a power source of equal voltage, frequency and rating as indicated on the product identification plate.
  4. Always use a power outlet that is grounded.
  5. Unplug the power cord when cleaning or when not in use.
  6. Do not operate with wet hands. Prevent water from spilling onto the product.
  7. Do not immerse or expose the productto rain, moisture or any other liquid.
  8. Do not leave the product running unattended. Do not tilt or turn over the product.
  9. Do not unplug while the productis operating.
  10. Do not unplug by pulling on the power cord.
  11. Do not use an extension cord or an adapter plug.
  12. Do not put objects on the product.
  13. Do not climb or sit on the product.
  14. Do not insert fingers or other objects into the air outlet.
  15. Do not touch the air inlet or the aluminum fins of the product.
  16. Do not operate the product if it is dropped, damaged or showing signs of product malfunction.
  17. Do not clean the appliance with any chemicals.
  18. Ensure the product is far away from fire, inflammable, or explosive objects.
  19. The product shall be installed in accordance with national wiring regulations.
  20. Do not use methods to accelerate the defrosting process or to clean, other than those recommended by the manufacture.
  21. The appliance shall be stored in a room without continuously operation sources (for example: open flames, an operating gas appliance or an operating electric heater).
  22. The appliance shall be stored so as to prevent mechanical damage from occurring.
  23. Do not piece or burn, even after use.
  24. Be aware that refrigerants may not contain an odour.
  25. Pipe-work shall be protected from physical damage and shall not be installed in an dis-ventilated space, if that space is smaller than 4m².
  26. Keep any required ventilation openings clear of obstruction.
  27. The appliance shall be stored in a well-ventilated area where the room size matches the room area as specified for operation.